CLMKS - 10-1902, DE-OX-ID (SEE SUPPL DATA)

  • MSDS: CLMKS
  • Manufacturer: GC THORSEN
  • Product Name: 10-1902, DE-OX-ID (SEE SUPPL DATA)
  • National Stock Number: 6850-00-473-5781
Product Identification

Product ID:10-1902, DE-OX-ID (SEE SUPPL DATA)
MSDS Date:11/02/1999
FSC:6850
NIIN:00-473-5781
Status Code:A
MSDS Number: CLMKS

Responsible Party
GC THORSEN
1801 MORGAN STREET
ROCKFORD, IL 61105
US

Emergency Phone: (800)424-9300

Info Phone: 815-968-9661

Preparer: M. WINSEL

Cage: 72653

Contractor
GC THORSEN
ROCKFORD, IL 61105 US

Telephone: 815-968-9661

Cage: 72653

Ingredients

KEROSENE

CAS: 8008-20-6

RTECS: OA5500000

OSHA PEL 100 MG/M3

ACGIH TLV: 100 MG/M3


REFINED MINERAL OIL (HYDROCARBON OILS, ALKANE OR PARAFFIN)

CAS: 8012-95-1

RTECS: PY8030000

OSHA PEL 5 MG/M3


PERCHLOROETHYLENE

CAS: 127-18-4

RTECS: KX3850000

OSHA PEL 50 PPM

ACGIH TLV: 170 MG/M3;25 PPM

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS

Hazards

LD50 LC50 Mixture:NONE PROVIDED BY MFR
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Health Hazards Acute and Chronic:EFFECTS OF OVEREXPOSURE: HEADACHE,
DIZZINESS, BRONCHITIS, NAUSEA, ANEMIA, PNEUMMONIA, CONVULSIONS,
IRRITATION OF MOUTH AND THROAT, NAUSEA, DROWSINESS.
Explanation of Carcinogenicity:KEROSENE& PERCHLOROETHYLENE ARE HUMAN
CARCINOGENS BY INHALATION OF MIST OR VAPORS
Effects of Overexposure:HEADACHE, DIZZINESS, BRONCHITIS, NAUSEA,
ANEMIA, PNEUMMONIA, CONVULSIONS, IRRITATION OF MOUTH AND THROAT,
NAUSEA, DROWSINESS
Medical Cond Aggravated by Exposure:NONE PROVIDED BY MFR

First Aid

First Aid:EYE: FLUSH WITH WATER FOR AT LEAST 15 MINUTES - CONSULT
PHYSICIAN. SKIN: WASH WITH SOAP AND WATER. INHALATION: REMOVE TO
FRESH AIR, PPOVIDE OXYGEN. INGESTION: GASTRIC LAVAGE, VEGETABLE
OIL. CONSULT P HYSICIAN IN ALL CASES OF OVEREXPOSURE..

Fire Fighting

Flash Point Method:COC
Flash Point:=75.C, 167.F
Lower Limits:1.2
Upper Limits:6.0
Extinguishing Media:CO2, CHEM FOAM
Fire Fighting Procedures:SCBA. HMIS: FIREFIGHTERS SHOULD USE NIOSH/MSHA
APPROVED SELF-CONTAINED BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:PERCHLORETHYLENE MAY BREAK DOWN IN FIRE
OR EXTREME HEAT TO PRODUCE HCI, CHLORINE GAS, CO & PHOSGENE

Accidental Release

Spill Release Procedures:ABSORB WITH CLOTH, PAPER TOWELS OR OTHER
ABSORBENT MATERIAL. STORE IN METAL CONTAINERS
Neutralizing Agent:NONE PROVIDED BY MFR

Handling

Handling and Storage Precautions:AVOID FLAME OR HIGH TEMPERATURES - CAN
MAY BURST AT TEMPERATURES ABOVE 120 DEG F
Other Precautions:NONE

Exposure Controls

Respiratory Protection:SCBA
Ventilation:MECHANICAL AS REQUIRED TO MEET TLV'S
Protective Gloves:BUTYL RUBBER GLOVES
Eye Protection:CHEMICAL GOGGLES
Other Protective Equipment:BUTYL RUBBER GLOVES
Work Hygienic Practices:NONE PROVIDED BY MFR
Supplemental Safety and Health
CONTD PRODUCT ID: DISCONTINUED PRODUCT - POSTED TO 19-1902 (NOTE ON
MSDS). THE INGREDIENTS DESCRIBED IN THE MSDS ARE IN DISAGREEMENT
WITH TIR; WHICH LISTS: REFINED MINERAL OIL 65%, EPC SOLVENT 10%, LE
CITHIN 10%, SYN CAMPHOR 10%, OIL OF WINTERGREEN 5%, & FLASH POINT
240 F.

Chemical Properties

HCC:T6
Boiling Pt:=180.C, 356.F
Melt/Freeze Pt:M.P/F.P Text:NONE PROVIDED BY MFR
Decomp Temp:Decomp Text:NONE PROVIDED BY MFR
Vapor Pres:13 MMHG
Vapor Density:UN
Spec Gravity:0.9
VOC Pounds/Gallon:729
pH:NONE PROVIDED
Viscosity:NONE PROVIDED BY MFR
Evaporation Rate & Reference:< 1
Solubility in Water:NOT
Appearance and Odor:CLEAR LIQUID - KEROSENE ODOR
Percent Volatiles by Volume:80
Corrosion Rate:NONE PROVIDED BY MFR

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Hazardous Decomposition Products:UNDER FLAME OR HIGH TEMPERATURES, HCI,
CARBON MONOXIDE, CHLORINE, PHOSGENE
Conditions to Avoid Polymerization:WILL NOT OCCUR

Disposal

Waste Disposal Methods:TREAT AS CHLORINATED HYDROCARBON WASTE -
LICENSED INCINERATOR. DISPOSAL MUST BE IN ACCORDANCE WITH LOCAL,
STATE AND FEDERAL REGULATIONS.

Regulatory

State Regulatory Information:USING THIS PERODUT WILL EXPOSE THE USER TO
A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.